diff --git a/home.admin/config.scripts/blitz.ups.sh b/home.admin/config.scripts/blitz.ups.sh index 7092d97a1..6e6b40557 100644 --- a/home.admin/config.scripts/blitz.ups.sh +++ b/home.admin/config.scripts/blitz.ups.sh @@ -39,7 +39,10 @@ if [ "$1" = "1" ] || [ "$1" = "on" ]; then sudo sed -i "s/^UPSCABLE.*/UPSCABLE usb/g" /etc/apcupsd/apcupsd.conf sudo sed -i "s/^UPSTYPE.*/UPSTYPE usb/g" /etc/apcupsd/apcupsd.conf sudo sed -i "s/^DEVICE.*/DEVICE/g" /etc/apcupsd/apcupsd.conf - sudo sed -i "s/^MINUTES.*/MINUTES 10/g" /etc/apcupsd/apcupsd.conf + # give the RaspiBlitz a minimum of 15 min to shutdown + sudo sed -i "s/^MINUTES.*/MINUTES 15/g" /etc/apcupsd/apcupsd.conf + # some APC UPS were not running stable below 90% Battery - so start shutdown at 95% remaining + sudo sed -i "s/^BATTERYLEVEL.*/BATTERYLEVEL 95/g" /etc/apcupsd/apcupsd.conf sudo sed -i "s/^ISCONFIGURED=.*/ISCONFIGURED=yes/g" /etc/default/apcupsd sudo sed -i "s/^SHUTDOWN=.*/SHUTDOWN=\/home\/admin\/XXshutdown.sh/g" /etc/apcupsd/apccontrol sudo sed -i "s/^WALL=.*/#WALL=wall/g" /etc/apcupsd/apccontrol