swresample: allow double precision beta value for the Kaiser window
Kaiser windows inherently don't require beta to be an integer. This was an arbitrary restriction. Moreover, soxr does not require it, and in fact often estimates beta to a non-integral value. Thus, this patch allows greater flexibility for swresample clients. Micro version is updated. Reviewed-by: Derek Buitenhuis <derek.buitenhuis@gmail.com> Reviewed-by: Michael Niedermayer <michael@niedermayer.cc> Signed-off-by: Ganesh Ajjanagadde <gajjanagadde@gmail.com>
This commit is contained in:
@@ -120,7 +120,7 @@ static const AVOption options[]={
|
||||
{ "blackman_nuttall", "select Blackman Nuttall windowed sinc", 0 , AV_OPT_TYPE_CONST, { .i64 = SWR_FILTER_TYPE_BLACKMAN_NUTTALL }, INT_MIN, INT_MAX, PARAM, "filter_type" },
|
||||
{ "kaiser" , "select Kaiser windowed sinc" , 0 , AV_OPT_TYPE_CONST, { .i64 = SWR_FILTER_TYPE_KAISER }, INT_MIN, INT_MAX, PARAM, "filter_type" },
|
||||
|
||||
{ "kaiser_beta" , "set swr Kaiser window beta" , OFFSET(kaiser_beta) , AV_OPT_TYPE_INT , {.i64=9 }, 2 , 16 , PARAM },
|
||||
{ "kaiser_beta" , "set swr Kaiser window beta" , OFFSET(kaiser_beta) , AV_OPT_TYPE_DOUBLE , {.dbl=9 }, 2 , 16 , PARAM },
|
||||
|
||||
{ "output_sample_bits" , "set swr number of output sample bits", OFFSET(dither.output_sample_bits), AV_OPT_TYPE_INT , {.i64=0 }, 0 , 64 , PARAM },
|
||||
{0}
|
||||
|
Reference in New Issue
Block a user