swresample: allow double precision beta value for the Kaiser window

Kaiser windows inherently don't require beta to be an integer. This was
an arbitrary restriction. Moreover, soxr does not require it, and in
fact often estimates beta to a non-integral value.

Thus, this patch allows greater flexibility for swresample clients.
Micro version is updated.

Reviewed-by: Derek Buitenhuis <derek.buitenhuis@gmail.com>
Reviewed-by: Michael Niedermayer <michael@niedermayer.cc>
Signed-off-by: Ganesh Ajjanagadde <gajjanagadde@gmail.com>
This commit is contained in:
Ganesh Ajjanagadde
2015-11-07 10:16:27 -05:00
parent 9ac61e73d0
commit 1bed09a30e
7 changed files with 9 additions and 9 deletions

View File

@@ -120,7 +120,7 @@ static const AVOption options[]={
{ "blackman_nuttall", "select Blackman Nuttall windowed sinc", 0 , AV_OPT_TYPE_CONST, { .i64 = SWR_FILTER_TYPE_BLACKMAN_NUTTALL }, INT_MIN, INT_MAX, PARAM, "filter_type" },
{ "kaiser" , "select Kaiser windowed sinc" , 0 , AV_OPT_TYPE_CONST, { .i64 = SWR_FILTER_TYPE_KAISER }, INT_MIN, INT_MAX, PARAM, "filter_type" },
{ "kaiser_beta" , "set swr Kaiser window beta" , OFFSET(kaiser_beta) , AV_OPT_TYPE_INT , {.i64=9 }, 2 , 16 , PARAM },
{ "kaiser_beta" , "set swr Kaiser window beta" , OFFSET(kaiser_beta) , AV_OPT_TYPE_DOUBLE , {.dbl=9 }, 2 , 16 , PARAM },
{ "output_sample_bits" , "set swr number of output sample bits", OFFSET(dither.output_sample_bits), AV_OPT_TYPE_INT , {.i64=0 }, 0 , 64 , PARAM },
{0}