@@ -333,13 +333,13 @@ for dev in $devices; do
|
||||
done
|
||||
|
||||
#####################################
|
||||
# INIT OF FRESH SYSTEM (ALL SYSTEMS)
|
||||
# PRE-SETUP INIT (ALL SYSTEMS)
|
||||
#####################################
|
||||
|
||||
if [ "${scenario}" != "ready" ] ; then
|
||||
|
||||
# write info for LCD
|
||||
echo "## INIT OF FRESH SYSTEM (ALL SYSTEMS)" >> $logFile
|
||||
echo "## PRE-SETUP INIT (ALL SYSTEMS)" >> $logFile
|
||||
/home/admin/_cache.sh set state "system-init"
|
||||
/home/admin/_cache.sh set message "please wait"
|
||||
|
||||
@@ -413,12 +413,12 @@ do
|
||||
done
|
||||
|
||||
#####################################
|
||||
# INIT OF FRESH SYSTEM (RASPBERRY PI)
|
||||
# PRE-SETUP INIT(RASPBERRY PI)
|
||||
#####################################
|
||||
|
||||
if [ "${scenario}" != "ready" ] && [ "${baseimage}" = "raspios_arm64" ]; then
|
||||
|
||||
echo "## INIT OF FRESH SYSTEM (RASPBERRY PI)" >> $logFile
|
||||
echo "## PRE-SETUP INIT(RASPBERRY PI)" >> $logFile
|
||||
|
||||
# set flag for reboot (only needed on raspberry pi)
|
||||
systemInitReboot=0
|
||||
@@ -573,15 +573,18 @@ if [ "${scenario}" != "ready" ] && [ "${baseimage}" = "raspios_arm64" ]; then
|
||||
|
||||
fi
|
||||
|
||||
#####################################
|
||||
# SYSTEM COPY OF FRESH SYSTEM
|
||||
#####################################
|
||||
############################
|
||||
############################
|
||||
# WHEN SETUP IS NEEDED
|
||||
############################
|
||||
|
||||
# on SETUP: ask user for format and copy of system
|
||||
if [ "${scenario}" = "setup:system" ]; then
|
||||
if [ "${scenario}" != "ready" ] ; then
|
||||
|
||||
/home/admin/_cache.sh set state "setup:system-wait"
|
||||
/home/admin/_cache.sh set message "user action needed"
|
||||
echo "## WHEN SETUP IS NEEDED " >> $logFile
|
||||
echo "/home/admin/config.scripts/blitz.data.sh status -inspect"
|
||||
/home/admin/config.scripts/blitz.data.sh status -inspect >> $logFile
|
||||
|
||||
# TODO: Add info if RaspberryPi, VM or LAPTOP
|
||||
|
||||
# put info into cache for ssh-dialog or web-dialog to pick up on
|
||||
/home/admin/_cache.sh set "system_setup_bootFromStorage" "${bootFromStorage}"
|
||||
@@ -590,6 +593,8 @@ if [ "${scenario}" = "setup:system" ]; then
|
||||
/home/admin/_cache.sh set "system_setup_storageDeviceName" "${storageDeviceName}"
|
||||
/home/admin/_cache.sh set "system_setup_storageSizeGB" "${storageDeviceName}"
|
||||
/home/admin/_cache.sh set "system_setup_storageWarning" "${storageWarning}"
|
||||
/home/admin/_cache.sh set "system_setup_storageBlockchainGB" "${storageBlockchainGB}"
|
||||
/home/admin/_cache.sh set "system_setup_storageMigration" "${storageMigration}"
|
||||
/home/admin/_cache.sh set "system_setup_systemDevice" "${storageDevice}"
|
||||
/home/admin/_cache.sh set "system_setup_systemDeviceName" "${storageDeviceName}"
|
||||
/home/admin/_cache.sh set "system_setup_systemSizeGB" "${storageDeviceName}"
|
||||
@@ -599,32 +604,95 @@ if [ "${scenario}" = "setup:system" ]; then
|
||||
/home/admin/_cache.sh set "system_setup_dataSizeGB" "${storageDeviceName}"
|
||||
/home/admin/_cache.sh set "system_setup_dataWarning" "${storageWarning}"
|
||||
|
||||
# add info if a flag shows that install medium was tried before
|
||||
if [ -f "/home/admin/systemcopy.flag" ]; then
|
||||
/home/admin/_cache.sh set "system_setup_secondtry" "1"
|
||||
else
|
||||
/home/admin/_cache.sh set "system_setup_secondtry" "0"
|
||||
fi
|
||||
|
||||
echo "## WAIT LOOP: USER SETUP SYSTEM" >> ${logFile}
|
||||
until [ "${state}" = "setup:system-result" ]
|
||||
# TODO: GET INFO FROM OTHE IMPLEMENTATIONS & COMPARE AGIANST LOCAL - not just LND
|
||||
# when migration check if for outdated btc, lnd, cln
|
||||
if [ "${scenario}" = "migration" ]; then
|
||||
migrationMode="normal"
|
||||
if [ "${hddVersionLND}" != "" ]; then
|
||||
source <(/home/admin/config.scripts/lnd.install.sh info "${hddVersionLND}")
|
||||
if [ "${compatible}" != "1" ]; then
|
||||
migrationMode="outdatedLightning"
|
||||
fi
|
||||
fi
|
||||
/home/admin/_cache.sh set migrationMode "${migrationMode}"
|
||||
fi
|
||||
|
||||
# TODO: REPLACE THIS OLD VALUES IN SSH & WEBUI
|
||||
/home/admin/_cache.sh set hddCandidate "${hddCandidate}"
|
||||
/home/admin/_cache.sh set hddGigaBytes "${hddGigaBytes}"
|
||||
/home/admin/_cache.sh set hddBlocksBitcoin "${hddBlocksBitcoin}"
|
||||
/home/admin/_cache.sh set hddGotMigrationData "${hddGotMigrationData}"
|
||||
/home/admin/_cache.sh set hddVersionLND "${hddVersionLND}"
|
||||
|
||||
# map scenario to setupPhase
|
||||
/home/admin/_cache.sh set "system_setup_askSystemCopy" "0"
|
||||
|
||||
if [ "${scenario}" = "setup:system" ]; then
|
||||
setupPhase="setup"
|
||||
infoMessage="Please start Setup"
|
||||
/home/admin/_cache.sh set "system_setup_askSystemCopy" "1"
|
||||
|
||||
if [ "${scenario}" = "setup:system" ]; then
|
||||
setupPhase="setup"
|
||||
infoMessage="Please start Setup"
|
||||
|
||||
elif [ "${scenario}" = "recover" ] || [ "${scenario}" = "recover:system" ]; then
|
||||
setupPhase="recovery"
|
||||
infoMessage="Please start Recovery"
|
||||
|
||||
# TODO: DETERMINE IF RECOVER OR UPDATE
|
||||
#setupPhase="update"
|
||||
|
||||
elif [ "${scenario}" = "migration" ]; then
|
||||
setupPhase="migration"
|
||||
infoMessage="Please start Migration"
|
||||
|
||||
else
|
||||
setupPhase="error"
|
||||
infoMessage="Unkonwn Setup Phase"
|
||||
fi
|
||||
|
||||
# signal "WAIT LOOP: SETUP" to LCD, SSH & WEBAPI
|
||||
/home/admin/_cache.sh set state "waitsetup"
|
||||
/home/admin/_cache.sh set message "${infoMessage}"
|
||||
/home/admin/_cache.sh set setupPhase "${setupPhase}"
|
||||
|
||||
#############################################
|
||||
# WAIT LOOP: USER SETUP/UPDATE/MIGRATION
|
||||
# until SSH or WEBUI setup data is available
|
||||
#############################################
|
||||
|
||||
echo "## WAIT LOOP: USER SETUP/UPDATE/MIGRATION" >> ${logFile}
|
||||
until [ "${state}" = "waitprovision" ]
|
||||
do
|
||||
|
||||
# give the loop a little bed time
|
||||
sleep 4
|
||||
|
||||
# check for updated state value from SSH-UI or WEB-UI for loop
|
||||
sleep 2
|
||||
source <(/home/admin/_cache.sh get state)
|
||||
|
||||
done
|
||||
|
||||
# get user result from cache
|
||||
source <(/home/admin/_cache.sh get "system_setup_result")
|
||||
echo "system_setup_result(${system_setup_result})" >> ${logFile}
|
||||
if [ "${system_setup_result}" = "ignore" ]; then
|
||||
echo "User wants NO system copy .. skipping." >> ${logFile}
|
||||
elif [ "${system_setup_result}" = "setup" ]; then
|
||||
# get the results from the SSH-UI or WEB-UI
|
||||
source ${setupFile}
|
||||
|
||||
####################
|
||||
# RUN SYSTEM COPY: SETUP
|
||||
# when user agreed to system copy to bootable drive (flag from setupFile)
|
||||
if [ "${copySystem}" = "1" ]; then
|
||||
|
||||
echo "User wants to format system" >> ${logFile}
|
||||
/home/admin/_cache.sh set state "setup:system-run"
|
||||
#####################################
|
||||
# SYSTEM COPY OF FRESH SYSTEM
|
||||
|
||||
echo "SYSTEM COPY OF FRESH SYSTEM" >> ${logFile}
|
||||
/home/admin/_cache.sh set state "systemcopy"
|
||||
/home/admin/_cache.sh set message "copying system"
|
||||
|
||||
# STORAGE
|
||||
if [ ${#storageDevice} -gt 0 ] && [ "${storageMountedPath}" = "0" ]; then
|
||||
@@ -665,23 +733,32 @@ if [ "${scenario}" = "setup:system" ]; then
|
||||
fi
|
||||
fi
|
||||
|
||||
# put flag file to signal change if boot medium was tried before
|
||||
# put flag file into old system
|
||||
touch /home/admin/systemcopy.flag
|
||||
|
||||
# TODO: DISABLE INSTALL MEDIUM
|
||||
# put setupFile to new system (so after reboot it can auto-provision)
|
||||
source <(/home/admin/config.scripts/blitz.data.sh status)
|
||||
mount /dev/${systemPartition} /mnt/disk_system
|
||||
echo "copy setupFile(${setupFile}) to /mnt/disk_system/home/admin/raspiblitz.setup" >> ${logFile}
|
||||
cp ${setupFile} /mnt/disk_system/home/admin/raspiblitz.setup
|
||||
|
||||
# TODO: disable old system boot
|
||||
|
||||
echo "DEBUG EXIT" >> ${logFile}
|
||||
exit 0
|
||||
|
||||
# reboot so that new system can start
|
||||
/home/admin/_cache.sh set state "reboot"
|
||||
/home/admin/_cache.sh set message "restarting system"
|
||||
shutdown -r now
|
||||
exit 0
|
||||
|
||||
else
|
||||
echo "Give user option to shutdown and change drives." >> ${logFile}
|
||||
/home/admin/_cache.sh set state "shutdown"
|
||||
/home/admin/_cache.sh set message ""
|
||||
shutdown now
|
||||
exit 1
|
||||
echo "Skipping System Copy" >> ${logFile}
|
||||
fi
|
||||
|
||||
|
||||
|
||||
fi
|
||||
|
||||
# on RECOVER/UPDATE: auto copy system
|
||||
@@ -735,113 +812,6 @@ fi
|
||||
/home/admin/_cache.sh set message "bootstrap-debug-exit"
|
||||
exit 1
|
||||
|
||||
############################
|
||||
############################
|
||||
# WHEN SETUP IS NEEDED
|
||||
############################
|
||||
|
||||
if [ ${isMounted} -eq 0 ]; then
|
||||
|
||||
# temp mount the HDD
|
||||
echo "Temp mounting (1) data drive" >> $logFile
|
||||
source <(/home/admin/config.scripts/blitz.datadrive.sh tempmount)
|
||||
echo "Temp mounting (1) result: ${isMounted}" >> $logFile
|
||||
|
||||
# write data needed for setup process into raspiblitz.info
|
||||
/home/admin/_cache.sh set hddCandidate "${hddCandidate}"
|
||||
/home/admin/_cache.sh set hddGigaBytes "${hddGigaBytes}"
|
||||
/home/admin/_cache.sh set hddBlocksBitcoin "${hddBlocksBitcoin}"
|
||||
/home/admin/_cache.sh set hddBlocksLitecoin "${hddBlocksLitecoin}"
|
||||
/home/admin/_cache.sh set hddGotMigrationData "${hddGotMigrationData}"
|
||||
/home/admin/_cache.sh set hddVersionLND "${hddVersionLND}"
|
||||
echo ""
|
||||
echo "HDD is there but not AutoMounted yet - Waiting for user Setup/Update" >> $logFile
|
||||
|
||||
# add some debug info to logfile
|
||||
echo "# df " >> ${logFile}
|
||||
df >> ${logFile}
|
||||
echo "# lsblk -o NAME,FSTYPE,LABEL " >> ${logFile}
|
||||
lsblk -o NAME,FSTYPE,LABEL >> ${logFile}
|
||||
echo "# /home/admin/config.scripts/blitz.datadrive.sh status"
|
||||
/home/admin/config.scripts/blitz.datadrive.sh status >> ${logFile}
|
||||
|
||||
# determine correct setup phase
|
||||
infoMessage="Please start Setup"
|
||||
setupPhase="setup"
|
||||
|
||||
if [ "${hddGotMigrationData}" != "" ]; then
|
||||
infoMessage="Please start Migration"
|
||||
setupPhase="migration"
|
||||
# check if lightning is outdated
|
||||
migrationMode="normal"
|
||||
if [ "${hddVersionLND}" != "" ]; then
|
||||
# get local lnd version & check compatibility
|
||||
source <(/home/admin/config.scripts/lnd.install.sh info "${hddVersionLND}")
|
||||
if [ "${compatible}" != "1" ]; then
|
||||
migrationMode="outdatedLightning"
|
||||
fi
|
||||
fi
|
||||
/home/admin/_cache.sh set migrationMode "${migrationMode}"
|
||||
|
||||
elif [ "${hddRaspiData}" = "1" ]; then
|
||||
|
||||
# determine if this is a recovery or an update
|
||||
# TODO: improve version/update detection later
|
||||
isRecovery=$(echo "${hddRaspiVersion}" | grep -c "${codeVersion}")
|
||||
if [ "${isRecovery}" = "1" ]; then
|
||||
infoMessage="Please start Recovery"
|
||||
setupPhase="recovery"
|
||||
else
|
||||
infoMessage="Please start Update"
|
||||
setupPhase="update"
|
||||
fi
|
||||
|
||||
fi
|
||||
|
||||
# signal "WAIT LOOP: SETUP" to LCD, SSH & WEBAPI
|
||||
echo "Displaying Info Message: ${infoMessage}" >> $logFile
|
||||
/home/admin/_cache.sh set state "waitsetup"
|
||||
/home/admin/_cache.sh set message "${infoMessage}"
|
||||
/home/admin/_cache.sh set setupPhase "${setupPhase}"
|
||||
|
||||
#############################################
|
||||
# WAIT LOOP: USER SETUP/UPDATE/MIGRATION
|
||||
# until SSH or WEBUI setup data is available
|
||||
#############################################
|
||||
|
||||
echo "## WAIT LOOP: USER SETUP/UPDATE/MIGRATION" >> ${logFile}
|
||||
until [ "${state}" = "waitprovision" ]
|
||||
do
|
||||
|
||||
# get fresh info about data drive (in case the hdd gets disconnected)
|
||||
source <(/home/admin/config.scripts/blitz.datadrive.sh status)
|
||||
if [ "${hddCandidate}" = "" ]; then
|
||||
/home/admin/config.scripts/blitz.error.sh _bootstrap.sh "lost-hdd" "Lost HDD connection .. triggering reboot." "happened during WAIT LOOP: USER SETUP/UPDATE/MIGRATION" ${logFile}
|
||||
sleep 8
|
||||
shutdown -r now
|
||||
sleep 100
|
||||
exit 0
|
||||
fi
|
||||
|
||||
# detect if network get deconnected again (call directly instead of cache)
|
||||
# --> "removing network cable" can be used as signal to shutdown clean on test startup
|
||||
source <(/home/admin/config.scripts/internet.sh status local)
|
||||
if [ "${localip}" = "" ]; then
|
||||
sed -i "s/^state=.*/state=errorNetwork/g" ${infoFile}
|
||||
sleep 8
|
||||
shutdown now
|
||||
sleep 100
|
||||
exit 0
|
||||
fi
|
||||
|
||||
# give the loop a little bed time
|
||||
sleep 4
|
||||
|
||||
# check for updated state value from SSH-UI or WEB-UI for loop
|
||||
source <(/home/admin/_cache.sh get state)
|
||||
|
||||
done
|
||||
|
||||
#############################################
|
||||
# PROVISION PROCESS
|
||||
#############################################
|
||||
@@ -855,8 +825,7 @@ if [ ${isMounted} -eq 0 ]; then
|
||||
|
||||
# get fresh data from setup file & data drive
|
||||
source <(/home/admin/config.scripts/blitz.datadrive.sh status)
|
||||
source ${setupFile}
|
||||
|
||||
|
||||
# special setup tasks (triggered by api/webui thru setupfile)
|
||||
|
||||
# FORMAT DATA DRIVE
|
||||
|
@@ -96,14 +96,14 @@ source /home/admin/raspiblitz.info
|
||||
############################################
|
||||
# DEFAULT: Basic Setup menu
|
||||
# user might default to from quick options
|
||||
if [ "${setupPhase}" == "setup" ]; then
|
||||
if [ "${setupPhase}" = "setup" ]; then
|
||||
|
||||
echo "# Starting basic setup dialog ..."
|
||||
/home/admin/setup.scripts/dialogBasicSetup.sh ${orgSetupPhase}
|
||||
menuresult=$?
|
||||
|
||||
# menu RECOVER menu option
|
||||
if [ "${menuresult}" == "4" ]; then
|
||||
if [ "${menuresult}" = "4" ]; then
|
||||
setupPhase="${orgSetupPhase}"
|
||||
/home/admin/_cache.sh set setupPhase "${setupPhase}"
|
||||
# proceed with provision (mark Password A to be set)
|
||||
|
Reference in New Issue